Checking The Pump Capacity
Remove the quick-release connector on the vacuum pump. Install: 9997108 with the plugged end on the pump
Connect: 9995230 on: 9997108 .
Install the connector for the pump. Read off the value on: 9995230 .
The value must be between 80-90 kPa negative pressure. If not replace the pump. See: VACUUM PUMP, BRAKE BOOSTER, REPLACING .