Checking Components And Wiring
- Ignition off
- Disconnect special tool
see 9511506
from the connector for the inflatable curtain.WARNING:
Under no circumstances use an ohmmeter or other live measuring instruments to take readings on a disconnected non-deployed pyrotechnical inflatable curtain. This could deploy the inflatable curtain
CAUTION:Do not touch the terminal pins in the SRS control module. There is a risk of static discharge. This could damage the SRS control module.
Check the female and male parts of the connectors for the Supplemental Restraint System Module (SRS) and the inflatable curtain. The cable terminals must not be damaged or pressed back
Check the cable between the control module for the Supplemental Restraint System Module (SRS) terminals #13A(13), #14A(14) and connector terminals #1, #3 on the rear left-hand inflatable curtain. Check for an open-circuit.
Remedy as necessary.
Other information:
- To access and replace the SRS control module and connector, see SUPPLEMENTAL RESTRAINT SYSTEM MODULE (SRS), REPLACING
- To access or replace the inflatable curtain connector, see IC (INFLATABLE CURTAIN) MODULE, REPLACING
- To connect the breakout box, see CONNECTING THE BREAKOUT BOX
- For information about the repair of SRS wiring, see CABLE HARNESS SRS SYSTEM, REPAIR
- For information about signals, see SIGNAL SPECIFICATION
- To fault-trace the wiring and terminals, see CHECKING WIRING AND TERMINALS .
- Continue
See: VERIFICATION