Circuit Test
The fault indicates an open-circuit in the cable from (or in) the lock unit. To determine in which circuit the fault is:
Remove the deadlock relay (2/115).
Remove the lock unit connector. Check the connector for contact resistance and oxidation.
Other information
- To expose the integrated relay/fusebox in the cargo compartment, see RELAY/FUSE BOX CARGO COMPARTMENT/REAR ELECTRONIC MODULE (REM), REPLACING
- To expose the lock unit, see LOCK MECHANISM, TAILGATE, REPLACING
- see CHECKING WIRING AND TERMINALS .
Was a fault detected?
- YES
OKAY: Troubleshooting has been completed.
- NO
Refer to CIRCUIT TEST (CONT.)
Begin by replacing the relay for deadlocking (2/115) in the integrated relay/fusebox in the cargo compartment. Check the relay base switches. Check for contact resistance and oxidation.
Other information
- To expose the integrated relay/fusebox in the cargo compartment, see RELAY/FUSE BOX CARGO COMPARTMENT/REAR ELECTRONIC MODULE (REM), REPLACING .
Was a fault detected?
- YES
OKAY: Troubleshooting has been completed.
- NO
Refer to CIRCUIT TEST (CONT.)