WASTEGATE Control Valve Adjustment: Check
Use: Universal oil, 1161657
see 9512986
NOTE:
Make sure that the special tool can move freely.
CAUTION:
Make sure that the component moves freely between the end positions.
Repeat the following steps until the component moves freely. Some minimal binding is permitted.
Fig 7: Adjusting Pressure to Specified Value and Verify No Leak (Ensure Pressure-Drop Remains Within Specified Values)
- Check that the pressure-drop remains within the specified values.
- See information about wastegate valve, see WASTEGATE VALVECAUTION: If the specified pressure is exceeded repeat the steps.
Note the value.
- See information about wastegate valve, see WASTEGATE VALVECAUTION: If the specified pressure is exceeded repeat the steps.
Note the value.
Calculate the average value.
Follow the instructions for wastegate valve, see WASTEGATE VALVE
If the average value is not according to specifications, adjust the stroke.