Checking The Power Supply And Ground Terminal
- Ignition off.
Check the cable between Central electronic module (CEM) #A41 (#41) and Remote Receiver Module (RRX) #A1 for open circuit.
Check the signal cable between central electronic module (CEM) terminals #A35 (#35) and Remote Receiver Module (RRX) #A5 for an open circuit, short-circuiting to ground, and short-circuiting to voltage.
Check the cable between remote control receiver (RRX) terminal #A3 and ground. Check for an open-circuit. Also check the ground terminal for oxidation.
Remedy the cables as necessary.
Other information
Was a fault detected?
- YES
Refer to VERIFICATION
- NO
Refer to CHECKING COMMUNICATION