Checking Wiring
- Ignition off
- Disconnect the switch hazard warning signal flashers connector.
Check signal cable for an open-circuit and short-circuit to supply voltage.
Take readings between:
- Central electronic module (CEM) terminal #B3 (#3) and hazard warning signal flashers switch connector terminal #1.
Remedy as necessary.
Other information
- Continue
Refer to VERIFICATION