Checking Component And Wiring
Instrument lighting
Check the voltage on the light switch module (LSM) connector terminal #12 to the output on the central electronic module (CEM). The voltage must be approximately 12 V when the instrument lighting is activated.
Check the control signal cable. Check for an open-circuit. Check for a short-circuit to supply voltage.
Take readings between:
- Central electronic module (CEM) terminal #H1 (#24) and light switch module (LSM) connector terminal #12.
Remedy as necessary.
Fuel tank filler cap
Check the voltage on the fuel tank filler cap connector terminal #2 to the output on the central electronic module (CEM). The voltage must be approximately 12 V when fuel tank filler cap unlocking is activated.
Check the control signal cable. Check for an open-circuit. Check for a short-circuit to supply voltage.
Take readings between:
- Central electronic module (CEM) terminal #C2 (#2) and fuel tank filler cap connector terminal #2.
Remedy as necessary.
Other information
- see CONNECTING THE BREAKOUT BOX (2004, 2005, 2006, 2007)
- see SIGNAL DESCRIPTION CENTRAL ELECTRONIC MODULE (CEM) (2004, 2005, 2006, 2007)
- see CONTROL MODULE RELAY BOX PASSENGER COMPARTMENT
- see LIGHTING SWITCH
- see FUEL TANK FILLER COVER
- see CHECKING WIRING AND TERMINALS
- Continue
Refer to VERIFICATION