Checking Component And Wiring
Check the signal cable between the central electronic module (CEM) and the alarm LED. Check for an open-circuit. Check for a short-circuit to supply voltage.
Take readings between:
- Central electronic module (CEM) terminal #B5 (#5) and alarm LED terminal #3.
Check the ground lead between the central electronic module (CEM) and the alarm LED. Check for an open-circuit. Check for a short-circuit to supply voltage.
Take readings between:
- Central electronic module (CEM) terminal #B28 (#28) and alarm LED terminal #5.
Remedy as necessary.
Other information
- see CONNECTING THE BREAKOUT BOX (2008, 2009, 2010, 2011)
- see SIGNAL DESCRIPTION CENTRAL ELECTRONIC MODULE (CEM) (2008, 2009, 2010, 2011)
- see LOCATION OF COMPONENTS (2010, 2011)
- see SUN SENSOR
- see CHECKING WIRING AND TERMINALS
Continue when the fault has been remedied.
- Continue
Refer to VERIFICATION