Checking the wiring
WARNING: This page is about a different car, the 2004 Volvo S40, 2003 Volvo S40, 2002 Volvo S40, 2001 Volvo S40, and 2000 Volvo S40. However, it is still accessible from the selected car via links, so may be relevant.
- Ignition off.
Check the connector on the leak diagnostic pump. Check for contact resistance and oxidation according to Contact resistance and oxidation .
Check the signal cable between engine control module (ECM) terminal #41 and leak diagnostic pump terminal #4. Check for a short-circuit to supply voltage according to Short-circuit to supply voltage. Permanent faults .
Remedy as necessary.
Try a new leak diagnostic pump if no fault is found during the above fault-tracing.
Other information:
- To connect the breakout box, see Connecting the breakout box. EMS 2000
- To access or replace the leak diagnostic pump, see Replacing the leak diagnostic pump
- For information about signals see Signal specification .
- Continue
Refer to Verification