Checking components and wiring
WARNING: This page is about a different car, the 2004 Volvo S40, 2003 Volvo S40, 2002 Volvo S40, 2001 Volvo S40, and 2000 Volvo S40. However, it is still accessible from the selected car via links, so may be relevant.
- Ignition off.
Check that the resistance between idle air control (IAC) valve terminals 1 and 2 is approximately 10 Ω at +20 °C.
Check signal cable between engine control module (ECM) terminal 64 and idle air control (IAC) valve terminal 2 for an intermittent short-circuit to ground. Remedy according to Short-circuit to ground, intermittent faults .
Other information
- To connect the breakout box, see Connecting the breakout box. EMS 2000 .
Courtesy of VOLVO CARS OF NORTH AMERICA.
- Continue
Refer to Information