Home >> Volvo >> 2008 >> S40 T-5, AWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 43 (Electronic Control Module (ECM) Diagnostic Trouble Codes - 3 Of 3 (644 Body)) >> ECM-87: Engine Cooling Fan (FC) High-Speed. Signal Too Low. Intermittent Fault (B4204T2 CVVT; 2000) >> Signal too low. Intermittent fault >> Checking cables

Checking cables

WARNING: This page is about a different car, the 2004 Volvo S40, 2003 Volvo S40, 2002 Volvo S40, 2001 Volvo S40, and 2000 Volvo S40. However, it is still accessible from the selected car via links, so may be relevant.

Check that the resistance between relay terminals 1 and 2 is approximately 75 Ω at +20 °C.

Check the signal cable between engine control module (ECM) #38 (half speed), #8 (full speed), #69 (air conditioning (A/C) cooling fan) and relay terminal 2 for an intermittent short-circuit to ground and remedy according to Short-circuit to ground, intermittent faults and for an intermittent open-circuit according to Open-circuit, intermittent faults .