LEMON Manuals: Even more car manuals for everyone
Home >> Volvo >> 2008 >> S40 T-5, AWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 37 (Electronic Control Module (ECM) Diagnostic Trouble Codes - 2 Of 3 (644 Body)) >> ECM-7D: Air Conditioning (A/C) Relay Signal. Signal Too Low. Intermittent Fault (B4204T2 CVVT; 2000) >> Intermittent fault, signal too low >> Checking wiring

Checking wiring

WARNING: This page is about a different car, the 2004 Volvo S40, 2003 Volvo S40, 2002 Volvo S40, 2001 Volvo S40, and 2000 Volvo S40. However, it is still accessible from the selected car via links, so may be relevant.

Check that the resistance between the air conditioning (A/C) relay terminals 1 and 2 is approximately 105 Ω at +20 °C.

Check the signal cable between the engine control module (ECM) terminal #68 and air conditioning (A/C) relay terminal 2 for an intermittent short-circuit to ground and remedy according to Short-circuit to ground, intermittent faults .

Other information 

Fig 1: Identifying Air Conditioning (A/C) Relay Connector Terminals
GLL114250Courtesy of VOLVO CARS OF NORTH AMERICA.
Fig 2: Identifying Ohmmeter
GLL101042Courtesy of VOLVO CARS OF NORTH AMERICA.
Fig 3: Identifying EMS2000
GLL111998Courtesy of VOLVO CARS OF NORTH AMERICA.