Home >> Volvo >> 2008 >> S40 T-5, AWD >> Repair and Diagnosis >> External Pages >> Different car >> Section 35 (Electronic Control Module (ECM) Diagnostic Trouble Codes - 1 Of 3 (644 Body)) >> ECM-2D: Turbocharger (TC) Control Valve Signal. Signal Too High. Intermittent Fault (B4204T2 CVVT; 2000) >> Signal too high. Intermittent fault >> Checking components and wiring

Checking components and wiring

WARNING: This page is about a different car, the 2004 Volvo S40, 2003 Volvo S40, 2002 Volvo S40, 2001 Volvo S40, and 2000 Volvo S40. However, it is still accessible from the selected car via links, so may be relevant.

Check that the resistance between turbocharger (TC) control valve terminals 1 and 2 is approximately 30 Ω at +20 °C.

Check the signal cable between engine control module (ECM) terminal 5 and turbocharger (TC) control valve terminal 2 for an intermittent short-circuit to supply voltage. Remedy according to Short-circuit to supply voltage, intermittent faults .