Checking light switch
Check the cable between lamp switch module terminal 3 and central electronic module (CEM) terminal 18A for an open-circuit according to Open-circuit, permanent faults and a short-circuit to ground according to Short-circuit to ground, permanent faults
Remedy as necessary.
Was a fault detected?
- YES
OKAY: Troubleshooting has been completed.
- NO
Refer to Replacing the component