Checking The Connectors
Check connector 54/3 and the connector for the central electronic module (CEM) for contact resistance and oxidation according to CONTACT RESISTANCE AND OXIDATION . Check for loose connections according to LOOSE CONNECTIONS (TERMINALS) . Remedy if necessary.
Check for any damage.
HINT: If the fault cause is found, reinstall the components, connectors etc.
HINT: If the fault cause is not found, do not reinstall the central electronic module (CEM) before continuing with fault-tracing.
Other information:
- For -2004, see: CENTRAL ELECTRONIC MODULE (CEM), REPLACING .
- For 2005-, see: CENTRAL ELECTRONIC MODULE (CEM), REPLACING .
- To connect the breakout box to the control module, see CONNECTING THE BREAKOUT BOX
- -2004: SIGNAL SPECIFICATION
- 2005-: SIGNAL SPECIFICATION
Was a fault detected?
- YES
OKAY: Troubleshooting has been completed.
- NO
Refer to CHECKING THE CABLE