Checking wire and replacement of component
Check the wire between the control unit 1A and reverse light contact 2 (3/10) for a short-circuit to voltage supply as described in Short-circuit to supply voltage. Permanent faults , and for an open circuit as described in Open-circuit, permanent faults .
Also check the connectors for a short circuit to voltage supply, as described in Short-circuit to supply voltage. Permanent faults , and for an open circuit as described in Open-circuit, permanent faults .
If no fault is found on the wire, check the function of the reversing lamp switch.
HINT: If reverse light contact is closed, the voltage between 1 and 2 on the contact is 0 V.
Do the necessary corrective action.
Additional information
- To access/replace the central electronic module (CEM), see Central electronic module (CEM), replacing .
- For information on signals and additional values, see Signal specification .
- To connect the test box, see Connecting the breakout box .
- Continue
OKAY: Troubleshooting has been completed.