LEMON Manuals: Even more car manuals for everyone
Home >> Volvo >> 2004 >> V40 Base >> Repair and Diagnosis >> Engine Performance >> System >> Engine Control Module (ECM) Diagnostic Trouble Codes - 2 Of 3 >> ECM-5C: Canister Purge (Cp) Valve Signal. Signal Too High. Intermittent Fault (B4204T3 (Ca) (Us); 2001-2003) >> Signal too high. Intermittent fault >> Checking components and wiring

Checking components and wiring

Check that the resistance in the canister purge (CP) valve between terminals #1 and #2 is approximately 21 Ω at +20 °C.

Check the signal cable between engine control module (ECM) terminal 4 and canister purge (CP) valve terminal #1. Check for an intermittent short-circuit to supply voltage according to Short-circuit to supply voltage, intermittent faults . Remedy if necessary.

Other information 

Fig 1: Identifying Canister Purge (CP) Valve Terminals
GLL111977Courtesy of VOLVO CARS OF NORTH AMERICA.
Fig 2: Identifying Ohmmeter
GLL101042Courtesy of VOLVO CARS OF NORTH AMERICA.
Fig 3: Identifying EMS2000
GLL111998Courtesy of VOLVO CARS OF NORTH AMERICA.