Checking the component and wiring
- Ignition off.
Check the cable between control module connector terminal #20A and ignition switch connector terminal #50. Check for a short-circuit to supply voltage or an open-circuit.
Other information
- The voltage must be 0 V if the key is in position 0, I or II.
- To access the connector, see:Central electronic module (CEM), replacing
- For connecting breakout box to Central Electronic Module (CEM):Connecting the breakout box
- -2004: Signal specification
- 2005-: Signal specification
- See Checking wiring and terminals. Permanent fault
Were any faults found in the cable?
- YES
Refer to Verification
- NO
Refer to Replacing a component