Intermittent fault
Check the transmission control module (TCM) and transmission connectors. Check for contact resistance and oxidation according to Contact resistance and oxidation .
Check the cables between control module terminal #A52 (#A52) and transmission connector terminal #D3. Check the cables between control module terminal #B10 (#A70) and transmission connector terminal #D4. Check for an intermittent open-circuit according to Open-circuit, intermittent faults .
HINT: Check solenoid SLT. Measure the resistance between terminals #D3 and #D4 on transmission connector A. The resistance should be 5-6 Ω at 20°C.
Remedy as necessary.
Other information:
- To connect the breakout box, see Connecting the breakout box
- To disconnect the transmission control module (TCM), see Transmission control module (TCM), replacing
- To disconnect the transmission connectors, see Connectors transmission, disconnecting / connecting
- For information about signals, see Signal description. Transmission control module (TCM) .
- Continue
Refer to Information