Checking the wiring
- Ignition off
- The breakout box connected
- Disconnect transmission connector D.
Check the cable between control module terminal #A49 (#A49) and transmission connector terminal #D5 (control module side). Check for a short-circuit to supply voltage. See Short-circuit to supply voltage. Permanent faults .
Check the cable between control module terminal #B7 (#A67) and transmission connector terminal #D6 (control module side). Check for a short-circuit to supply voltage. See Short-circuit to supply voltage. Permanent faults .
Check the wiring in the circuit for short-circuits to other cables in the circuit. Use the relevant Wiring Diagram.
Remedy as necessary.
Other information:
- To connect the breakout box, see Connecting the breakout box
- To disconnect the transmission connectors, see Connectors transmission, disconnecting / connecting
- For information about signals, see Signal description. Transmission control module (TCM) .
Was a fault found in the wiring?
- YES
Refer to Verification
- NO
Refer to Checking the wiring and component