Checking the wiring
- Ignition off
- The breakout box connected
- Disconnect transmission connector D.
Check the cable between transmission control module (TCM) terminal #A51 (#A51) and transmission connector terminal #D1 (control module side). Check for a short-circuit to supply voltage. See Short-circuit to supply voltage. Permanent faults .
Check the cable between control module terminal #B9 (#A69) and transmission connector terminal #D2 (control module side). Check for a short-circuit to supply voltage. See Short-circuit to supply voltage. Permanent faults .
Also check against the other cables in the circuit. Use the relevant wiring diagram.
Remedy as necessary.
Other information:
- To connect the breakout box, see Connecting the breakout box
- To disconnect the transmission connectors, see Connectors transmission, disconnecting / connecting
- For information about signals, see Signal description. Transmission control module (TCM) .
Was a fault detected?
- YES
Refer to Verification
- NO
Refer to Checking the wiring and component