Checking the wiring
- Ignition off.
Check the cable between control module terminal #A48 (#A48) and transmission connector terminal #C3 (control module side). Check for a short-circuit to supply voltage according to Short-circuit to supply voltage. Permanent faults . Also check against the other cables in the circuit. Use the relevant wiring diagram.
Other information:
- To connect the breakout box, see Connecting the breakout box
- To disconnect the transmission connectors, see Connectors, transmission, disconnecting / connecting
- For information about signals, see Signal description. Transmission control module (TCM) .
Was a fault detected?
- YES
Refer to Verification
- NO
Refer to Checking the wiring and component