Intermittent fault
Check the control module for the gear selector and the solenoid connectors. Check for intermittent contact resistance according to Loose connections (terminals) .
Check the cable between the control module for the gear selector and the shift lock solenoid. Check for an intermittent open-circuit according to Open-circuit, intermittent faults .
Remedy as necessary.
Other information:
- To check or replace the shift lock solenoid, see Solenoid, back-up (reverse) inhibitor, replacing .
- Continue
Refer to Information