Checking solenoid SL
- Ignition off
- Connect the breakout box to the control module connector (transmission side).
Check solenoid SL by measuring the resistance between terminals #A51 (#A51) and #A53 (#A53).
When the transmission is cold (20°C), the resistance must be 10-11 Ω. When the transmission is at operating temperature (150°C), the resistance must not exceed 16 Ω.
Other information:
- To connect the breakout box, see Connecting the breakout box
- For information about signals, see Signal specification .
Was the resistance OK?
- YES
- NO
Refer to Checking the wiring