Checking the wiring and component
Check the cable between transmission control module (TCM) terminal #A37 (#A37) and transmission connector terminal #D7 (control module side). Check for a short-circuit to ground. See Short-circuit to ground, permanent faults .
Remedy as necessary.
Other information:
- To connect the breakout box, see Connecting the breakout box
- To disconnect the transmission connectors, see Connectors, transmission, disconnecting / connecting
- For information about signals, see Signal description. Transmission control module (TCM) .
Was a fault detected?
- YES
Refer to Verification
- NO
Refer to Checking the cable and component