Intermittent fault
Remedy contact resistance and oxidation in the control module and automatic transmission connectors. See Contact resistance and oxidation
Check the cable between control module terminal #37 (#A37) and transmission connector (control module side) terminal #L (#A11). Check for an intermittent short-circuit to ground. See Short-circuit to ground, intermittent faults .
Check the cable between control module terminal #55 (#A55) and transmission connector (control module side) terminal #M (#A12). Check for an intermittent short-circuit to ground. See Short-circuit to ground, intermittent faults .
Remedy as necessary.
Other information:
- To connect the breakout box, see Connecting the breakout box
- To connect the breakout box to the transmission connector, see Connecting the breakout box, GM automatic transmissions
- For information about signals, see Signal specification .
- Continue
Refer to Information