Home >> Volvo >> 2004 >> S80 Base, 2.5 59, FWD >> Repair and Diagnosis >> Transmission >> Automatic Trans >> Transmission Control Module (TCM) Diagnostic Trouble Codes - 2 Of 5 >> TCM-0014: Lock-Up Solenoid SL. Signal Too Low. Intermittent Fault (4T65EV; 1999-2005) >> Signal too low. Intermittent fault >> Intermittent fault

Intermittent fault

Check the cable between control module terminal #51 (#A51) and transmission connector #T (#A17) for an intermittent short-circuit to ground according to Short-circuit to ground, intermittent faults .

Check the wiring between control module terminal 53 (#A53) and transmission connector #E (#A5) for an intermittent short-circuit to ground according to Short-circuit to ground, intermittent faults .

HINT: With the ignition off and the control module disconnected, the resistance between control module terminal 51 (#A51) and ground (breakout box #53) should be 11-15 Ω. 

Remedy as necessary.

Other information: 

Fig 1: Identifying Breakout Box
GLL100304Courtesy of VOLVO CARS OF NORTH AMERICA.
Fig 2: Identifying Ohms Display
GLL101042Courtesy of VOLVO CARS OF NORTH AMERICA.