Checking solenoid SL
- Ignition off
- Disconnect the automatic transmission connector
- Connect adapter 9511505 and breakout box 9813190 to the transmission connector (transmission side)
- Connect an ohmmeter between terminals E (#A5) and T (#A17).
The solenoid SL resistance must be between 10 and 15 Ω.
Other information:
- To connect the breakout box to the transmission connector, see Connecting the breakout box, GM automatic transmissions
- For information about signals, see Signal specification .
Was the resistance OK?
- YES
Refer to Checking the wiring
- NO
Refer to Checking the wiring and component