Intermittent fault
- Ignition off.
Check the cable between control module terminal 51 (#A51) and transmission connector (control module side) terminal T #A17 for an intermittent open-circuit according to Open-circuit, intermittent faults .
Check the wiring between control module terminal 53 (#A53) and transmission connector #E (#A5) for an intermittent open-circuit according to Open-circuit, intermittent faults .
Remedy as necessary.
Other information:
- To connect the breakout box, see Connecting the breakout box .
- To connect the breakout box to the transmission connector, see Connecting the breakout box, GM automatic transmissions .
- For information about signals, see Signal specification .
- Continue
Refer to Information