Checking the cables in the circuit for solenoid STH
- Ignition off
- Connect the breakout box to the transmission
- Disconnect the control module.
- Disconnect the transmission connector
- Connect adapter
9511505
and breakout box
9813190
to the transmission connector (control module side).
Check the cable between control module terminal #A52 and transmission connector terminal #C (#A3) for a short-circuit to ground.
Check the cable between control module terminal #A70 (#B10) and transmission connector terminal #D (#A4) for a short-circuit to ground.
Other information:
- To connect the breakout box to the control module, see Connecting the breakout box
- To connect the breakout box to the transmission connector, see Connecting the breakout box, GM automatic transmissions
- For information about signals, see Signal specification
- See Checking wiring and terminals. Permanent fault
Was the wiring OK?
- YES
Refer to Checking the wiring and component
- NO