Intermittent fault
Check the cable between control module terminal #A50 and transmission connector terminal #A (#A1) (control module side). Check for an intermittent short-circuit to ground. See Short-circuit to ground, intermittent faults . Check for contact resistance and oxidation. See Contact resistance and oxidation .
Check the cable between control module terminal #A53 and transmission connector terminal #E (#A5) (control module side). Check for an intermittent short-circuit to ground. See Short-circuit to ground, intermittent faults . Check for contact resistance and oxidation. See Contact resistance and oxidation .
Remedy as necessary.
Other information:
- To connect the breakout box, see Connecting the breakout box
- To connect the breakout box to the transmission connector, see Connecting the breakout box, GM automatic transmissions
- For information about signals, see Signal specification .