Intermittent fault
Check the control module and transmission connectors for contact resistance and oxidation according to Contact resistance and oxidation
Check the cable between control module terminal #50 (#A50) and transmission connector terminal #C1. Check for an intermittent open-circuit according to Open-circuit, intermittent faults .
- Check the circuit for solenoid S1: Switch off the ignition. Disconnect the control module. Measure the resistance between terminals #A50 (#A50) and #A53 (#A53) on the breakout box. The resistance must be 12-16 Ω.
Remedy as necessary.
Other information:
- To connect the breakout box, see Connecting the breakout box
- To disconnect the transmission connectors, see Connectors, transmission, disconnecting / connecting
- For information about signals, see Signal description. Transmission control module (TCM) .
- Continue
Refer to Information