LEMON Manuals: Even more car manuals for everyone
Home >> Volvo >> 2004 >> S80 Base, 2.5 59, FWD >> Repair and Diagnosis >> Transmission >> Automatic Trans >> Transmission - Removal, Replacement And Installation - 2 Of 2 >> Transmission, Automatic (Ambulance; 2001-2002) >> Solenoid control system, replacing >> Replacing and checking solenoids >> Checking the resistance of SLT, SLS and SLU

Checking the resistance of SLT, SLS and SLU

Fig 1: Identifying S1-S5, SLT, SLU And SLS Solenoids
GLL109420Courtesy of VOLVO CARS OF NORTH AMERICA.
NOTE:

Readings should be taken at approximately 20°C.

Solenoid SLT, SLS and SLU 

Measure the resistance between both the pins in the solenoid connector.

Correct value: 5.0-5.6 Ω.

If the value of any of solenoids SLT, SLS and SLU is incorrect 

Replace the control system. See Replacing the control system .

The control system is calibrated together with the solenoids.