LEMON Manuals: Even more car manuals for everyone
Home >> Volvo >> 2004 >> S80 Base, 2.5 59, FWD >> Repair and Diagnosis >> Transmission >> Automatic Trans >> Transmission - Removal, Replacement And Installation - 2 Of 2 >> Transmission, Automatic (Ambulance; 2001-2002) >> Solenoid control system, replacing >> Replacing and checking solenoids >> Check the resistance in S1-S5

Check the resistance in S1-S5

Fig 1: Identifying S1-S5, SLT, SLU And SLS Solenoids
GLL109420Courtesy of VOLVO CARS OF NORTH AMERICA.
NOTE:

Readings should be taken at approximately 20°C.

Solenoid S1 

Measure the resistance between the pin in the solenoid connector and the transmission ground terminal.

Correct value: 12-16 Ω.

Solenoids S2-S5 

Measure the resistance between the pin in the solenoid connector and the transmission ground terminal.

Correct value: 11-15 Ω.

If the resistance of any of solenoids S1-S5 is incorrect 

Replace the solenoid. See Replacing solenoids S1-S5 .