Conversion table standardized diagnostic trouble codes/Volvo diagnostic trouble codes: Table
| SAE/ISO diagnostic trouble code (DTC) | Volvo DII diagnostic trouble code (DTC) | Diagnostic trouble code (DTC) designation | Fault type |
| P0218 | TCM-0046 | Oil temperature | Too high oil temperature |
| P0560 P0561 |
TCM-009A | Battery voltage | Signal too low |
| P0600 | TCM-E000 | Communication control module | Incorrect communication |
| P0602 P0614 |
TCM-0048 | Control module | Defective software |
| P0605 P0601 |
TCM-0049 | Control module | Internal error. Intermittent error |
| P0605 P0601 |
TCM-0049 | Control module | Internal error. Permanent error |
| P0605 P062F |
TCM-0099 | Control module | Internal error |
| P0610 | TCM-E003 | Configuration error | Incorrect configuration. Intermittent error |
| P0610 | TCM-E003 | Configuration error | Incorrect configuration. Permanent error |
| P0702 | TCM-0060 | Control module | Internal error |
| P0702 | TCM-0120 | Control module | Internal error |
| P0702 | TCM-0121 | Control module | Internal error |
| P0702 | TCM-0122 | Control module | Internal error |
| P0702 | TCM-0123 | Control module | Internal error |
| P0702 | TCM-0124 | Control module | Internal error |
| P0705 | TCM-0039 | Gear-shift position sensor | Faulty signal |
| P0711 | TCM-0045 | Oil temperature sensor | Faulty signal |
| P0712 | TCM-0043 | Oil temperature sensor | Signal too low |
| P0713 | TCM-0044 | Oil temperature sensor | Signal too high |
| P0715 | TCM-0087 | Gearbox input speed sensor | Signal too high |
| P0715 P2160 |
TCM-0089 | Gearbox input speed sensor | Signal too low |
| P0716 | TCM-0024 | Gearbox input speed sensor | Incorrect signal. Intermittent error |
| P0716 | TCM-0024 | Gearbox input speed sensor | Incorrect signal. Permanent error |
| P0717 | TCM-0023 | Gearbox input speed sensor | Signal missing. Intermittent error |
| P0717 | TCM-0023 | Gearbox input speed sensor | Signal missing. Permanent error |
| P0720 P0502 |
TCM-0081 | Vehicle speed sensor (VSS) | Signal too high |
| P720 P0503 |
TCM-0083 | Vehicle speed sensor (VSS) | Signal too low |
| P0721 P0501 |
TCM-0020 | Vehicle speed sensor (VSS) | Incorrect signal. Intermittent error |
| P0721 P0501 |
TCM-0020 | Vehicle speed sensor (VSS) | Incorrect signal. Permanent error |
| P0722 P0500 |
TCM-001F | Vehicle speed sensor (VSS) | Signal missing. Intermittent error |
| P0722 P0500 |
TCM-001F | Vehicle speed sensor (VSS) | Signal missing. Permanent error |
| P0731 | TCM-0028 | Gear 1 | Incorrect gear ratio |
| P0732 | TCM-0029 | Gear 2 | Incorrect gear ratio |
| P0733 | TCM-002A | Gear 3 | Incorrect gear ratio |
| P0734 | TCM-002B | Gear 4 | Incorrect gear ratio |
| P0735 | TCM-002C | Gear 5 | Incorrect gear ratio |
| P0736 | TCM-0027 | Reverse gear | Incorrect gear ratio |
| P0740 P0811 |
TCM-002F | Lock-up function | Slipping or not engaged |
| P0744 | TCM-002E | Lock-up | The transmission jerks when lock-up engages |
| P0748 P0963 |
TCM-0116 | Throttle solenoid SLT | Signal too high. Permanent error |
| P0749 P0963 |
TCM-0116 | Throttle solenoid SLT | Signal too high. Intermittent error |
| P0750 P0960 |
TCM-0117 | Throttle solenoid SLT | Signal missing. Permanent error |
| P0751 P0960 |
TCM-0117 | Throttle solenoid SLT | Signal missing. Intermittent error |
| P0751 | TCM-000B | Shift solenoid S1 | Hydraulic malfunction |
| P0752 P0962 |
TCM-0118 | Throttle solenoid SLT | Signal too low. Permanent error |
| P0753 P0974 |
TCM-0001 | Shift solenoid S1 | Signal too high |
| P0753 | TCM-0002 | Shift solenoid S1 | Signal missing |
| P0753 P0973 |
TCM-0003 | Shift solenoid S1 | Signal too low |
| P0753 P0962 |
TCM-0118 | Throttle solenoid SLT | Signal too low. Intermittent error |
| P0756 | TCM-000C | Shift solenoid S2 | Hydraulic malfunction |
| P0758 P0977 |
TCM-0007 | Shift solenoid S2 | Signal too high |
| P0758 | TCM-0008 | Shift solenoid S2 | Signal missing |
| P0758 | TCM-0009 | Shift solenoid S2 | Signal too low |
| P0762 | TCM-0115 | Shift solenoid S3 | Hydraulic malfunction |
| P0763 P0980 |
TCM-0101 | Shift solenoid S3 | Signal too high |
| P0763 | TCM-0102 | Shift solenoid S3 | Signal missing |
| P0763 P0979 |
TCM-0103 | Shift solenoid S3 | Signal too low |
| P0768 P0983 |
TCM-0107 | Shift solenoid S4 | Signal too high |
| P0768 | TCM-0108 | Shift solenoid S4 | Signal missing |
| P0768 P0982 |
TCM-0109 | Shift solenoid S4 | Signal too low |
| P0773 P0986 |
TCM-010A | Shift solenoid S5 | Signal too high |
| P0773 | TCM-010B | Shift solenoid S5 | Signal missing |
| P0773 P0985 |
TCM-010C | Shift solenoid S5 | Signal too low |
| P0778 P0967 |
TCM-010D | Lock-up solenoid SLU | Signal too high. Intermittent error |
| P0778 P0967 |
TCM-010D | Lock-up solenoid SLU | Signal too high. Permanent error |
| P0778 P0964 |
TCM-010F | Lock-up solenoid SLU | Signal missing. Intermittent error |
| P0778 P0964 |
TCM-010F | Lock-up solenoid SLU | Signal missing. Permanent error |
| P0778 P0966 |
TCM-0110 | Lock-up solenoid SLU | Signal too low. Intermittent error |
| P0778 P0966 |
TCM-0110 | Lock-up solenoid SLU | Signal too low. Permanent error |
| P0785 P0780 |
TCM-0100 | Poor gearshifting quality | . |
| P0798 P0971 |
TCM-0112 | System pressure solenoid SLS | Signal too high. Permanent error |
| P0799 P0971 |
TCM-0112 | System pressure solenoid SLS | Signal too high. Intermittent error |
| P0800 P0968 |
TCM-0113 | System pressure solenoid SLS | Signal missing. Permanent error |
| P0801 P0968 |
TCM-0113 | System pressure solenoid SLS | Signal missing. Intermittent error |
| P0802 P0970 |
TCM-0114 | System pressure solenoid SLS | Signal too low. Permanent error |
| P0803 P0970 |
TCM-0114 | System pressure solenoid SLS | Signal too low. Intermittent error |
| P0810 P1700 |
TCM-012A | Neutral check | Incorrect connection |
| P0810 P1516 |
TCM-012B | Neutral check | No neutral check |
| P0811 P0894 |
TCM-012C | Neutral check | The engine RPM oscillates |
| P0826 | TCM-0096 | Quickshift sensor | Faulty signal |
| P0860 | TCM-0093 | Communication control module gear lever | Signal too high |
| P0860 | TCM-0094 | Communication control module gear lever | Signal missing |
| P0860 | TCM-0095 | Communication control module gear lever | Signal too low |
| P0928 | TCM-0091 | Solenoid P-position shift-lock | Signal missing |
| P0930 | TCM-0092 |
Solenoid P-position shift-lock | Signal too low |
| P0931 | TCM-0090 | Solenoid P-position shift-lock | Signal too high |