SRS-00B0: Diagnostic trouble code information
Condition
If the circuit voltage is high or low for more than 10 seconds, diagnostic trouble code SRS-00B0 is displayed.
Substitute Value
- Nothing.
Possible Source
Signal too high:
- Signal wire short circuited to voltage supply
- Faulty side impact sensor.
Signal too low:
- Signal wire short circuited to ground
- Faulty side impact sensor.
Fault symptom[s]
- SRS warning lamp on.