Checking components
- Ignition off.
- Disconnect connector from the left inflatable curtain
- Connect the special tool 9511506 to the left inflatable curtain connector.
-
WARNING:
Never use an ohmmeter or any other charged measuring instrument on a disconnected, undeployed explosive inflatable curtain. There is a risk that the inflatable curtain could be deployed
NOTE:The special tool must be checked and fault-free. If the special tool is defective, the wrong diagnosis will be displayed and troubleshooting will be more difficult.
- Ignition on, wait for approximately 10 seconds.
Read the diagnostic trouble codes.
If the diagnostic trouble code status changes from permanent to intermittent fault, replace the left inflatable curtain.
Additional information:
- To access/replace the left inflatable curtain, see IC (inflatable curtain) module, replacing
- To check the special tool, see Calibration .
Does the status of the diagnostic trouble code change?
- YES
Refer to Verification
- NO
Refer to Checking components and wires