Checking components and wiring
- Ignition off
- Disconnect special tool
9511506
from the connector for the left-hand inflatable curtain.WARNING:
Under no circumstances use an ohmmeter or other live measuring instruments to take readings on a disconnected, non-deployed, pyrotechnical inflatable curtain. This could deploy the inflatable curtain
CAUTION:Do not touch the terminal pins in the SRS control module. There is a risk of static discharge. This could damage the SRS control module.
Check the cable between SRS control module terminals #21A (21) and #22A (22) and connector terminals #1 and #3 on the left-hand inflatable curtain for a short-circuit to ground according to Short-circuit to ground, permanent faults .
Remedy as necessary.
Other information:
- To access and replace the SRS control module and connector, see Supplemental restraint system module (SRS), replacing
- To access and replace the connector for the left-hand inflatable curtain (IC), see IC (inflatable curtain) module, replacing
- To connect the breakout box, see Connecting the breakout box
- With the ignition off and the connectors for the left-hand inflatable curtain and for the SRS control module disconnected, the resistance between the inflatable curtain connector terminals #1 and #3 (SRS control module side) and ground should be infinite
- For information about the repair of SRS wiring, see Cable harness SRS system, repair
- For other values:
1999-2004
- See Signal specification .
2005-2006
- See Signal specification .
Continue when the fault has been remedied.
- Continue
Refer to Verification