Components resistance values
Resistance values are given at +20°C (+68°F) unless otherwise stated.
| Component | Other |
|---|---|
| Water temperature sensor | Resistance: 10°C (50°F): approximately 20 k 20°C (68°F): approximately 11 k 30°C (86°F): approximately 8 k 75°C (167°F): approximately 1.5 k 90°C (194°F): approximately 900 |
| Heater fan | Wire resistance between connections: 1-10 |
| Water pump | Wire resistance between connections: 1-10 |
| Fuel pump | Wire resistance between connections: approximately 8 |
| Glow plug | Resistance: approximately 1 |
| Overheat thermostat | Resistance: Not activated < 3 Activated > 10 k |