Verification - Manual climate control: Verification
HINT: After the repair it is necessary to check that the fault has been rectified.
- Ignition off.
- Connect the connectors, install the components, etc.
- Ignition on.
- Blower motor on.
Check that damper motor position changes by activating and de-activating from control panel. The values given below are the standard values that the damper motor positions should give.
NOTE:Blower motor must be in operation to activate the damper motors.
- Left/right damper motor temperature, 0-100%
- Recirculation damper motor, 40-100%
- Damper motor air distribution, defroster approximately 0%, floor/defroster approximately 19%, floor approximately 39%, ventilation approximately 83%.
Does damper motor work?
- YES
VERIFIED: Troubleshooting has been completed.
- NO
Refer to Information