Fault-tracing information: Verification
HINT: After the repair it is necessary to check that the fault has been rectified.
- Ignition off.
- Connect connectors, install components, etc.
- Ignition on.
Check blower switch signal by turning blower switch between minimum and maximum settings.
The value should vary between 0.05 and 4.95 V.
Is the value OK?
- YES
VERIFIED: Troubleshooting has been completed.
- NO
Refer to Information