Condition, fuel trim bank X:
Fuel trim can assume 5 different conditions:
- no fuel trim, the start conditions have not been met.
.
This condition occurs at the crank or immediately after start before fuel trim has started
- fuel trim with 2 probes
.
This situation occurs during driving when both probes are used during fuel trim (part load).
- no fuel trim, operation with predefined values
.
This situation occurs during hard acceleration or during fuel shut-off when there is no fuel trim and operation is under predefined values.
- no fuel trim, operation with system fault
.
This situation occurs when an earlier diagnostic trouble code (DTC) was stored that caused the fuel trim to be disabled
- fuel trim with one probe (front)
.