Home >> Volvo >> 2004 >> S80 Base, 2.5 59, FWD >> Repair and Diagnosis >> Engine Performance >> Testing & Diagnosis >> Engine Control Module (ECM) Diagnostic Trouble Codes - 9 Of 11 >> ECM-8410: 5 Volt Power Supply. Signal Too Low. Permanent Fault (B6284T; 1999-2001) >> Signal too low. Permanent fault >> Checking the wiring

Checking the wiring

Check the power supply cable between control module terminal #A39 (#A39) and mass air flow (MAF) sensor terminal #4. Check for a short-circuit to ground.

Check the power supply cable between control module terminal #A39 (#A39) and boost pressure sensor terminal #1. Check for a short-circuit to ground.

Check the power supply cable between control module terminal #A39 (#A39) and air conditioning (A/C) pressure sensor terminal #3. Check for a short-circuit to ground.

Check the power cable between control module terminal #B10 (#B20) and fuel tank pressure sensor connector terminal #3. Check for a short-circuit to ground.

HINT: Read off the 5-volt power supply by clicking on the VCT2000 symbol. 

Remedy as necessary.