Checking the wiring
Check signal cable for an open-circuit and short-circuit to supply voltage.
Take readings between:
- Engine Control Module (ECM) terminal #B48 (#B58) and terminal #2 of control module cooling fan.
If no faults are found via the aforementioned fault tracing, replace the control module cooling fan.
Remedy as necessary.
Other information:
- To connect the breakout box, see Connecting the breakout box
- For information about signals on 5 cylinder engines, see Signal specification
- For information about signals on 6 cylinder engines:
- For 6 cylinder engines -2001, see Signal specification
- For 6 cylinder engines 2002-, see Signal specification
- For 6 cylinder engines -2004, see Signal specification
- For 6 cylinder engines 2005-, see Signal specification .
- See Checking wiring and terminals .
- Continue
Refer to Information