Checking wiring and connectors
Check the injector connector. Check for contact resistance and oxidation. Check for loose connections.
Check the cable between injector terminal 2 and control module:
- terminal #A16 (#A16) (ECM 2310)
- terminal #A34 (#A34) (ECM 2320)
- terminal #A15 (#A15) (ECM 2330)
- terminal #A33 (#A33) (ECM 2340)
- terminal #A14 (#A14) (ECM 2350).
Check the power supply between system relay terminal 3 and injector terminal 1. Check for an for an intermittent open-circuit.
Other information
- To connect the breakout box / access the control module, see Connecting the breakout box
- To access or replace the injector, see Injectors/pulsation dampers, replacing
- For information about signals, see Signal specification
- See Contents .
- Continue
Refer to Information