Home >> Volvo >> 2004 >> S80 Base, 2.5 59, FWD >> Repair and Diagnosis >> Engine Performance >> Testing & Diagnosis >> Engine Control Module (ECM) Diagnostic Trouble Codes - 2 Of 11 >> ECM-1200: Intake Air Temperature (IAT) Sensor. Signal Too Low. Intermittent Fault (B6284T; 1999-2001) >> Signal too low. Intermittent fault >> Checking wiring and connectors

Checking wiring and connectors

Check the intake air temperature (IAT) sensor connector. Check for contact resistance and oxidation. Check for loose connections.

Check the signal cable between control module terminal #A5 (#A5) and intake air temperature (IAT) sensor connector terminal #1. Check for an intermittent open-circuit. Check for an intermittent short-circuit to supply voltage.

Check the ground lead between control module terminal #A60 (#A60) and intake air temperature (IAT) sensor connector terminal #2. Check for an intermittent open-circuit.

Other information 

Fig 1: Identifying Intake Air Temperature (IAT) Sensor Connector Terminals
GLL104010Courtesy of VOLVO CARS OF NORTH AMERICA.
Fig 2: Identifying Ohmmeter
GLL101042Courtesy of VOLVO CARS OF NORTH AMERICA.
Fig 3: Identifying Temperature Sensor - Intake (Turbocharged Engines Only, 2002-2004)
GLL102919Courtesy of VOLVO CARS OF NORTH AMERICA.