Checking for a short-circuit
Check the cable between the sun roof module (SRM) and the roof lamp module. Check for a short-circuit to supply voltage.
UEM-0070 Sun roof. Faulty signal
The sun roof module (SRM) terminal #3A and roof lamp module terminal #2B.
UEM-0070 Sun roof. Faulty signal
The sun roof module (SRM) terminal #7A and roof lamp module terminal #1B.
Replace the cable if a fault is found.
Other information:
- For further information about signals and other values, see Signal specification
- To access the roof lamp module connector, see Interior lighting and upper electronic module (UEM), replacing .
- To access the sun roof module (SRM) connector, see Control module, sun roof, replacing (1999-) or Control module, sun roof, replacing (2003-2006)
- See Checking wiring and terminals .
- Continue
Refer to Checking the cable