LEMON Manuals: Even more car manuals for everyone
Home >> Volvo >> 2004 >> S80 Base, 2.5 59, FWD >> Repair and Diagnosis >> Electrical >> Motors, Switches, Relays >> Fault Tracing - General Information >> Fault Tracing >> Description of frozen values >> Identification of the damper motor module (DMM), LIN bus 2

Identification of the damper motor module (DMM), LIN bus 2

The parameter indicates the status after identification of the damper motors.

Temporary ID not OK = the climate control module (CCM) has been unable to allocate the damper motors a temporary ID during identification.

Defroster not OK = failed identification of the damper motor module (DMM) defroster.

Recirculation not OK = failed identification of the damper motor module (DMM) recirculation.

Temperature left not OK = failed identification of the damper motor module (DMM) temperature left.

Temperature right not OK = failed identification of the damper motor module (DMM) temperature right.

Air distribution not OK = failed identification of the damper motor module (DMM) air distribution.

OK = identification OK.