Connecting the breakout box
- Ignition off
- Remove the fuses
- See Central electronic module (CEM), replacing
Connect breakout box 9511428 to the adapter.
Central electronic module (CEM)
- Connect adapter 9512971 to the control module connectors A, B, C and D
- For connector A, terminals #A1-#A32 correspond to terminals #1-#32 on the breakout box
- For connector B, terminals #B1-#B32 correspond to terminals #1-#32 on the breakout box
- For connector C, terminals #C1-#C36 correspond to terminals #1-#36 on the breakout box
- For connector D terminals #D1-#D60 correspond to terminals #1-#60 on the breakout box.
NOTE:
Before the control module can be checked and measurements taken, the removed fuses must first be installed.
Other information