Home >> Volvo >> 2004 >> S80 Base, 2.5 59, FWD >> Repair and Diagnosis >> Electrical >> Motors, Switches, Relays >> AEM, CEM & Rem Diagnostic Trouble Codes - 9 Of 12 >> CEM-8F29: Relay, Front Screen Washer Motor. Signal Too High. Permanent Fault (1999-2004) >> Signal missing. Permanent fault >> Checking the relay and supply

Checking the relay and supply

Check that relay 2/92 is correctly connected. Check that the relay is not defective.

The following applies only to CEM-8F2B.

HINT: The fault may have been caused by an open-circuit in the supply to the relay. The voltage must be 12 V at both terminals #1 and #5 for relay 2/92. Check fuse 11B/16 in particular. 

Remedy as necessary.

Fig 1: Identifying Voltage Display
GLL101041Courtesy of VOLVO CARS OF NORTH AMERICA.
Fig 2: Identifying Relay Terminals
GLL104197Courtesy of VOLVO CARS OF NORTH AMERICA.

Was a fault detected?